Why does water stand on a roof that is meant to drain?
A flat roof drains only by a slight fall. Settling of the deck, a worn membrane or a blocked drain can leave a low spot where water stays.
A low-slope deck can settle or sag slightly over time, and the low spot becomes a pool. Water sitting in that pool on the membrane day after day speeds up aging and pushes at every seam. The pool may also freeze and thaw, and each cycle works the membrane harder than rain alone would.
Filling the low spot is not always the answer. Sometimes the drain can be moved, tapered insulation added or the deck reshaped. A roofer checks which option the building allows before deciding, and the choice is written into the scope.
Can a flat roof be patched, or does it need recovering?
Patching works for a local failure. A roof with wide blistering, many failed seams or old layers beneath is generally better recovered or replaced than patched.
A patch is a sound choice when the rest of the membrane is in good condition and the failure is confined to one spot. The patch overlaps sound material by a good margin, and its edges are bonded so they do not lift. Many small patches across one roof are a sign the membrane has reached the end of its life.
Recovering means laying a new covering over the old, which can work where the existing layers are sound and the structure can take the added weight. The roofer checks the deck and the drains before recommending it, because the added layer has to be carried.
How is a leak traced on a flat roof?
Water can travel well away from its entry point across a flat deck, so the search runs from the ceiling stain back toward the drains and seams.
On a flat roof water usually runs toward the lowest point before it finds a way in, which can be some distance from the stain below. The ceiling is checked for the wettest area, and the roof above is searched along the line of the nearest drain or seam.
A controlled water test, where a section is kept under a shallow pool while someone watches the ceiling below, is one way to confirm the entry point. It is done carefully, and the water is removed once the test is complete.
How often should a flat roof be checked?
At least twice a year, and after any heavy rain or long freeze, because flat roofs usually show trouble first as standing water.
A check in spring, after the snow has gone, and another in autumn before the leaves and snow arrive, catches most drainage problems in time. The drains are the first thing to clear, since a blocked drain turns an ordinary rain into a weight problem on the deck.
From a safe, fixed access point, a building manager can look for ponding, blisters and loose debris. The roofer's visit is the detailed check, with the membrane probed and the flashing read at each junction.